CLEANING AND INSPECTION CONTINUED
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
2. Dry parts with compressed air.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
000128
Door Switch
000128
1. Install door switch (Figure 14, Item 1), two star washers (Figure 14, Item 7), nuts (Figure 14, Item 6), washers
(Figure 14, Item 5), and bolts (Figure 14, Item 4) on door frame.
2. Connect electrical connector (Figure 14, Item 3) to door switch (Figure 14, Item 1).
3. Install new tiedown straps (Figure 14, Item 2) on door switch (Figure 14, Item 1) cable.
END OF TASK