BATTERY POWER DISCONNECT
BATTERY POWER DISCONNECT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  942    943    944    945    946  947  948    949    950    951    952  
img
.
TM 5-3805-292-23
0142
REMOVAL
000142
C AU T I O N
Ensure the fuse is removed first. This will allow disconnection of the battery cables without
arcing. Failure to follow this caution may result in damage to equipment.
1. Remove fuse (Figure 1, Item 4).
N OT E
Note positive and negative connecting points. Tag cables prior to removal to ensure
correct installation.
Disconnect negative (black) cables first.
2. Remove two covers (Figure 1, Item 1), nuts (Figure 1, Item 3), and four battery cables (Figure 1, Item 2) from
batteries (Figure 1, Item 5).
Figure 1. Battery Compartment.
0142
END OF TASK