BATTERY POWER DISCONNECT - Continued
Figure 1. Battery Cables and Single-Point Power Distribution Block.

Field Maintenance Manual For M400T And M400W
Page Navigation
  944    945    946    947    948  949  950    951    952    953    954  
img
. . . . . . . .
8
TM 5-3805-292-23
0143
FIELD MAINTENANCE
-
BATTERY CABLES REPLACEMENT
0143
REMOVAL, INSTALLATION
INITIAL SETUP
Tools and Special Tools
Equipment Conditions
0
0
Tool Kit, General Mechanic's (WP 0178, Item
Machine parked on level ground (TM 5-3805-
33)
292-10)
0
0
Parking brake engaged (TM 5-3805-292-10)
0
Materials/Parts
0
Battery access door opened (TM 5-3805-292-
Rag, Wiping (WP 0179, Item 19)
10)
0
0
Strap, Tiedown, Electrical Components (WP
Battery power disconnected (WP 0142)
0
0179, Item 29)
0
ROPS tilted (WP 0134)
0
Tag, Marker (WP 0179, Item 30)
0
Estimated Time to Complete
Lockwasher (6)
0
0
1.2 Hr
0
References
0
TM 5-3805-292-23P, Figure 70 and 71
0
WARN I N G
To avoid injury, eye protection and acid-resistant gloves must be worn when working
around batteries. Do not smoke, use open flame, make sparks, or create other ignition
sources around batteries. If a battery is giving off gases, it can explode and cause injury.
Remove all jewelry such as rings, ID tags, watches, and bracelets. If jewelry or a tool
contacts a battery terminal, a direct short will cause instant heating.
Sulfuric acid contained in batteries can cause serious burns. If battery corrosion or
electrolyte makes contact with skin, eyes, or clothing, take immediate action to stop the
corrosive burning effects.
Eyes. Flush with cold water for no less than 15 minutes and seek medical
attention immediately.
Skin. Flush with large amounts of cold water until all acid is removed. Seek
medical attention as required.
Internal. If corrosion or electrolyte is ingested, drink large amounts of water or
milk. Follow with milk of magnesia, beaten egg, or vegetable oil. Seek medical
attention immediately.
Clothing/Equipment. Wash area with large amounts of cold water. Neutralize acid
with baking soda or household ammonia.
Arcing or sparks may occur if battery cables contact any metal surfaces of machine during
removal. Ensure they do not contact metal surfaces.
Failure to follow these warnings ma result in injury to personnel.
y