Table 1. Air Conditioner Does Not Blow Cold When A/C Is Turned On and Temperature Control Panel Is Set on Maximum Cool - Continued.
Figure 5. Auxiliary Condenser.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1203    1204    1205    1206    1207  1208  1209    1210    1211    1212    1213  
img
.
TM 5-3805-298-23-1
0118
Table 1. Air Conditioner Does Not Blow Cold When A/C Is Turned On and
Temperature Control Panel Is Set on Maximum Cool - Continued.
0118
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Air Conditioner Does Not
6. Inspect auxiliary condenser cover
Auxiliary Condenser Cover OK -
Blow Cold When A/C Is
(Figure 4, Item 3) for dirt, debris,
Proceed to step 7.
Turned On and Temperature
bent louvers (Figure 4, Item 4), or
Auxiliary Condenser Cover Has Dirt
Control Panel Is Set on
damage.
or Debris - Remove dirt and debris from
Maximum Cool Continued
auxiliary condenser cover.
Proceed to Test Step 8.
Auxiliary Condenser Cover Bent or
Damaged - Replace auxiliary
condenser cover (WP 0419).
Proceed to Test Step 8.
7. Remove four bolts
(Figure 4, Item 1), washers
(Figure 4, Item 2), and auxiliary
condenser cover (Figure 4, Item 3)
from machine.