TM 5-3805-298-23-1
0118
Table 1. Air Conditioner Does Not Blow Cold When A/C Is Turned On and
Temperature Control Panel Is Set on Maximum Cool - Continued.
0118
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Air Conditioner Does Not
Auxiliary Condenser Cover OK -
Blow Cold When A/C Is
(Figure 4, Item 3) for dirt, debris,
Proceed to step 7.
Turned On and Temperature
bent louvers (Figure 4, Item 4), or
Control Panel Is Set on
damage.
or Debris - Remove dirt and debris from
Maximum Cool Continued
auxiliary condenser cover.
Proceed to Test Step 8.
Auxiliary Condenser Cover Bent or
Damaged - Replace auxiliary
condenser cover (WP 0419).
Proceed to Test Step 8.
7. Remove four bolts
(Figure 4, Item 1), washers
(Figure 4, Item 2), and auxiliary
condenser cover (Figure 4, Item 3)
from machine.
Figure 4. Auxiliary Condenser Cover.
0118