TM 5-3805-298-23-2
0155
Table 1. Kickout System Will Not Operate or Operates Improperly.
0155
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Kickout System Will Not
Operate or Operates
Always inspect wiring harness connectors that are involved in the circuit.
Improperly
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure and
that all connections are in good condition. If a problem with the
connection is found, correct the problem and verify that this malfunction
or diagnostic code is active before performing this procedure.
Perform open or short-circuit test at each wiring harness connection to
identify the correct wiring harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
Test Step 1. Check for Active
Diagnostic Codes.
Diagnostic Codes Not Active
Connect MSD, select Transmission
Proceed to Test Step 2.
924 and check for active diagnostic
codes (WP 0008).
Diagnostic Codes Active Refer to
(WP 0005) and repair active diagnostic
codes first.
Proceed to Test Step 60.
Test Step 2. Verify Implement
Operation.
1. Verify kickout switch is in OFF
position (TM 5-3805-298-10).
2. Verify all implements operate
All Implements Operate Properly
properly (TM 5-3805-298-10).
Proceed to Test Step 3.
One or More Implements Fail to
Operate Properly Diagnose and
repair all implement malfunctions
(WP 0005).
Proceed to Test Step 60.