TM 5-3805-298-23-2
0155
Table 1. Kickout System Will Not Operate or Operates Improperly Continued.
0155
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Kickout System Will Not
Resistance 5.0 Ohms or Less
Operate or Operates
Proceed to step 8.
between connector C-C22
Improperly - Continued
terminal 7 (WP 0012, Figure 232)
Replace lower cab wiring harness
and ground.
(WP 0291).
Proceed to Test Step 60.
Resistance 5.0 Ohms or Less
Proceed to Test Step 11.
between connector C-C22
terminal 8 (WP 0012, Figure 232)
Replace lower cab wiring harness
and ground.
(WP 0291).
Proceed to Test Step 60.
Test Step 11. Test Signal Circuits to
1. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-298-10).
2. Set implement disable switch to
unlock position
(TM 5-3805-298-10).
3. Set kickout switch to ON position
(TM 5-3805-298-10).
Voltage Changes Accordingly
Proceed to step 5.
between connector C-C22
Voltage Fails to Change Accordingly
terminal 2 and terminal 7
Proceed to Test Step 45.
(WP 0012, Figure 232) as follows:
NOTE
Yellow LED should turn on within 60 seconds to initialize sensor.
a. Have assistant touch magnet to
back side of lift kickout position
sensor (Figure 11, Item 2) and
remove magnet. If yellow LED
(Figure 11, Item 1) is
illuminated, it will turn OFF.
Wait 1 to 60 seconds and
yellow LED will turn ON.
0155-16