TM 5-3805-298-23-2
0155
Table 1. Kickout System Will Not Operate or Operates Improperly Continued.
0155
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Kickout System Will Not
kickout fuse (TM 5-3805-298-10).
Operate or Operates
between kickout fuse terminals.
Improperly - Continued
Proceed to Test Step 26.
Resistance Greater Than 5.0 Ohms -
Replace kickout fuse (TM 5-3805-298-
10).
Proceed to Test Step 29.
Test Step 26. Test Voltage to Kickout
Switch.
1. Remove console instrument panel
for access to wiring harness
connectors (WP 0264).
2. Disconnect connector C-C37
(WP 0012, Figure 241) from
kickout switch (WP 0012,
Figure 242).
3. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-298-10).
4. Set implement disable switch to
unlock position
(TM 5-3805-298-10).
Voltage 18 to 26 V Proceed to Test
Step 27.
between connector C-C37
Voltage Less Than 18 V Proceed to
terminal 2 (WP 0012, Figure 241)
Test Step 28.
and ground.
Test Step 27. Test Lower Cab Wiring
Harness for High Resistance or
Open.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
Resistance 5.0 Ohms or Less
Replace kickout switch (WP 0264).
between connector C-C37
Proceed to Test Step 60.
terminal 3 (WP 0012, Figure 241)
and connector C-C9 terminal 6
Replace lower cab wiring harness
(WP 0012, Figure 153).
(WP 0291).
Proceed to Test Step 60.
Test Step 28. Test Lower Cab Wiring
Harness for High Resistance or
Open.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
0155-31