TM 5-3805-298-23-2
0197
CLEANING AND INSPECTION
000197
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK
INSTALLATION
000197
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
1. Install two new gaskets (Figure 2, Item 4) and exhaust manifold (Figure 2, Item 1) on engine.
2. Apply sealing compound to 12 bolts (Figure 2, Item 2).
3. Install 12 spacers (Figure 2, Item 3) and bolts (Figure 2, Item 2) on exhaust manifold (Figure 2, Item 1).
Figure 2. Gaskets, Exhaust Manifold, Spacers, and Bolts.
0197