TM 5-3805-262-206-1. TRANSMISSION MAINTENANCE (CONT) b. Control Valve Linkage (cont).INSPECTION(1)( 2)(3)( 4)(5)(6)(7)NOTEReplace all parts determined to be defective in following steps .Check cable assembly (4) for smooth movement. Check that cable slidessmoothly in cable housing.Inspect cable assembly (4) for kinks and broken wires strands. Check thatcovering is not cracked, split, cut, or broken. Check that four seals (6)are not cut,cracked, or split. Replace seals if any of these conditionsare seen.Rotate bearings (36 and 68) and check that movement is smooth and notrough or tight. Check that bearings are not chipped.Inspect spring (12) for cracks or signs of permanent set.Inspect bushing (19) for scores or nicks. Check seal (18) for damage. Ifseal or bushing requires replacement, use a 1-1/4 inches diameter sleeveand press from block assembly (17). To reinstall, press bushing and sealinto block assembly using 1-1/4 inches diameter sleeve. Refer to illus-tration below for positioning of bushing and seal .I n s p e c t r e t a i n i ngInspect remainingdamaged threads.INSTALLATION (SHEET 1 OF 4)( 1 ) I n s t a l l r e t a i n i n gring (69) for deformation, breaks or cracks.parts for cracks, bent condition, and crossed orring (69) and position two bearings (68) on bellcrank(70) shaft. Position bellcrank (70) with bearings (68) installed on pivotplate (64). Secure bearings using four capscrews (67), lock washers (66),and nuts (65).(2) Position assembled bellcrank (70) and pivot plate (64) on side of trans-mission and secure bellcrank using two lock washers (63) and capscrews( 6 2 ).6-14