TM 5-3805-262-20
6-1. TRANSMISSION MAINTENANCE (CONT)
c. Transmission Pump and Oil Filter and Lines (cont).
(2) Oil Filter and Lines. This task covers removal, cleaning, inspection, and
i n s t a l l a t i o n o f o i l f i l t e r a n d l i n e s .
TOOLS: No. 1 Common Organizational Maintenance Tool Kit
Fixed open end wrench set
Socket wrench set, 3/8 inch drive
MATERIALS/PARTS: Clean cloths (Appendix C, item 1)
Cleaning solvent P-D-680 (Appendix C, item 2)
NOTE
PRELIMINARY PROCEDURE: Engine right side panels removed (page 9-14) and
transmission oil filter removed (page 6-9).
REMOVAL
( a)
(b)
(c)
(d)
(e)
( f )
(g)
At right side of vehicle, tag return tube (3) then loosen and disconnect
two compression nuts (2) and remove return tube (3) from loader.
Remove two adapters (4) and 0-rings (5).
Tag supply tube (7) then loosen and disconnect two compression nuts (6);
remove supply tube (7) from vehicle.
Remove adapter (8) and 0-ring (9) from transmission.
At filter head (15), remove elbow (10) and 0-ring (11).
Support filter head (15) and remove four capscrews (12), lock washers
(13), and washers (14); remove filter head (15) and spacer (16).
Support mounting bracket (19). Remove two capscrews (17) and lock
washers (18); remove mounting bracket (19).
CLEANING (SHEET 1 OF 2)
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a
a r e a . A v o i d c o n t a c t w i t h s k i n , e y e s a n d c l o t h e s a nd
v a p o r s . D o n o t u s e n e a r o p e n f l a m e o r e x c e s s i v e h e at
w h e n u s i n g i t.
F a i l u r e t o d o s o c o u l d c a u s e s e r i o us
b e c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e sh
attention immediately. I f c o n t a c t w i t h s k i n o r c l o t h es
w i t h l a r g e a m o u n t s o f w a t e r . I f c o n t a c t w i t h e y e s i s
with water and get medical aid immediately.
w e l l v e n t i l a t ed
d o n t b r e a t h e
and dont smoke
i n j u r y . I f y o u
air and medical
i s m a d e , f l u s h
made, wash eyes
(a) Clean all parts using clean cloths moistened with cleaning solvent
P-D-680. Dry using clean cloths.
6-22