TM 5-3805-262-34INSTALLATION (SHEET 1 OF 3)Dry cleaning solvent P-D-680 used to cleanWear protective goggles and gloves andparts is toxic and flammable.use only in a well ventilatedarea. Avoid contact with skin, eyes and clothes and don’t breathevapors. Do not use near open flame or excessive heat and don’t smokewhen using it. Failure to do so could cause serious injury. If you be-come dizzy while using cleaning solvent, get fresh air and medicalattention immediately. If contact with skin or clothes is made, flushwith large amounts of water. If contact with eyes is made, wash eyeswith water and get medical aid immediately.(1)(2)(3)Clean cylinder head fuel injec-tor mounting surface using cleancloth moistened with cleaningsolvent P-D-680. Dry using cleancloth.Install guide nut (part of borecleaning tool) in fuel injectorbore.Install bore cleaning tool inguide nut. Turn bore cleaningtool clockwise using a ratchetwrench.Compressed air used for cleaningpurposes will not exceed 30 psi.Use only with effective chipguarding and personal protectiveequipment(goggles/shield,gloves, etc). Failure to do socould cause serious injury toeyes and possible blindness. Ifyou hurt your eyes or if aforeign object is blown into youreyes,seek medical attentionimmediately.(4)Remove bore cleaning tool andblow out bore using compressedair to remove particles.3-113
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business