TM 5-3805-262-34
3-17. FLOW CONTROL VALVE MAINTENANCE (CONT)
CLEANING AND INSPECTION
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
Wear protective goggles and gloves and use only in a well ventilated
area. Avoid contact with skin, eyes and clothes and don-t breathe
vapors. Do not use near open flame or excessive heat and dont smoke
when using it. Failure to do so could cause serious injury. If you be-
come dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush
with large amounts of water.
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
a.
Clean all parts using cleaning solvent P-D-680. Dry using clean cloths.
b.
Inspect valve body for cracks or damage. Replace flow control valve if valve
body requires replacement.
C.
Inspect remaining parts for cracks, distortion, or damage. Replace as neces-
sary.
3-568