TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
MACHINE ECM
0007 00
Table 2. MID 081 - Machine Control System.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0041 03
Power Supply (8V)
This diagnostic code is recorded when powertrain ECM reads sensor
Voltage Above Normal.
supply circuit voltage as higher than normal because output of sensor
supply to battery has shorted or transmission oil temperature sensor is
faulty. When this code is generated, lockup clutch is disabled, there is
hesitation during direction shifts, and calibrations will not function.
0041 04
Power Supply (8V)
This diagnostic code is associated with power supply for sensors. FMI
Shorted to Ground.
04 means that ECM has determined sensor circuit voltage is below
normal due to a failed sensor, circuit shorted to ground, or ECM failure
(such a failure is unlikely).
0070 03
Switch (Parking Brake)
This diagnostic code is associated with parking brake switch. Switch is
Voltage Above Normal.
connected to two ECM inputs. One contact is open and one contact is
grounded during proper operation because normally open contact and
normally closed contact are open or contact currently closed to ground
is shorted to +batt circuit.
0070 04
Switch (Parking Brake)
This diagnostic code is associated with parking brake switch. Switch is
Shorted to Ground.
connected to two ECM inputs: "Normally Open" and "Normally
Closed". One input is open and other is grounded during proper
operation. FMI 04 means ECM has determined that "Normally Open"
and "Normally Closed" circuits are grounded.
0096 03
Sensor (Fuel Level)
This diagnostic code is recorded when ECM reads signal voltage of fuel
Voltage Above Normal.
level sending unit and voltage is too high. Possible causes of this
diagnostic code are:
Sender has failed.
Return sender circuit is open in machine harness.
Signal circuit in machine harness is shorted to a
source of positive voltage.
Signal circuit in machine harness is open or sender
is disconnected.
ECM has failed (such a failure is unlikely).
This failure causes fuel gage to always indicate an empty fuel tank or
to intermittently indicate an empty fuel tank.
0096 04
Sensor (Fuel Level)
This diagnostic code is recorded when ECM reads signal voltage of fuel
Shorted to Ground.
level sending unit and voltage is too low because sender failed, signal
circuit in machine harness is shorted to ground, or ECM has failed (such
a failure is unlikely). This failure causes fuel gage to always indicate
an empty fuel tank or to intermittently indicate an empty fuel tank.
0007 00-13