TM 5-3805-290-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
MACHINE ECM - CONTINUED
0007 00
Table 2. MID 081 - Machine Control System - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0271 03
Action Alarm
This diagnostic code is associated with action alarm. FMI 03 means
Voltage Above Normal.
ECM has determined alarm circuit voltage is above normal due to failed
alarm, alarm energize circuit is shorted to +batt circuit, or failed cluster
(such a failure is unlikely).
0271 05
Action Alarm
This diagnostic code is associated with action alarm. FMI 05 means
Open Circuit.
ECM has determined alarm circuit current is below normal.
Possible causes of this diagnostic code are:
Alarm energize circuit is open.
Alarm return circuit is open.
Alarm has failed.
ECM has failed (such a failure is unlikely).
0271 06
Action Alarm
This diagnostic code is associated with action alarm. FMI 06 means that
Shorted to Ground.
ECM has determined that current of alarm circuit is above normal.
Possible causes of this diagnostic code are:
Energize circuit of alarm is shorted to ground.
Alarm has failed.
ECM has failed (such a failure is unlikely).
0291 03
Solenoid (Demand Fan)
This diagnostic code is associated with demand fan solenoid. FMI 03
Voltage Above Normal.
means ECM has determined solenoid circuit voltage is above normal
because solenoid has failed, solenoid energize circuit is shorted to +batt
circuit, or ECM has failed (such a failure is unlikely).
0291 05
Solenoid (Demand Fan)
This diagnostic code is associated with demand fan solenoid. FMI 05
Open Circuit.
means ECM has determined solenoid current is below normal because
solenoid energize circuit is open, solenoid return circuit is open,
solenoid has failed, or ECM has failed (such a failure is unlikely). When
this diagnostic code occurs, fan speed will increase to maximum.
0291 06
Solenoid (Demand Fan)
This diagnostic code is associated with demand fan solenoid. FMI 06
Shorted to Ground.
means ECM has determined solenoid current is above normal because
solenoid energize circuit is shorted to ground, solenoid has failed, or
ECM has failed (such a failure is unlikely). ECM will log diagnostic
code. When this diagnostic code occurs, fan speed will increase to
maximum.
0367 02
Switch (Ride Control)
This diagnostic code is associated with ride control switch. FMI 02
Incorrect, Intermittent, or means ECM has determined one of two ride control switch signal wires
Erratic Data.
is grounded intermittently due to failed wiring harness, failed switch,
or failed ECM (such a failure is unlikely).
0007 00-15