TM 5-3805-290-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
MACHINE ECM - CONTINUED
0007 00
Table 2. MID 081 - Machine Control System - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0177 03
Temperature Sensor
This diagnostic code is associated with temperature sensor
(Transmission Oil)
(transmission oil). FMI 03 means ECM has determined voltage of
Open or Short to +Batt.
sensor circuit is above normal.
Possible causes of this diagnostic code are:
Signal circuit for sensor is open.
Signal circuit for sensor is shorted to +batt circuit.
Sensor has failed.
Power circuit or ground circuit has failed.
ECM has failed (such a failure is unlikely).
When this diagnostic code occurs, brake oil diverter solenoid is turned
off.
0177 04
Temperature Sensor
This diagnostic code is associated with temperature sensor
(transmission oil). FMI 04 means ECM has determined voltage of
(Transmission Oil)
position sensor circuit is below normal because sensor signal circuit is
Shorted to Ground.
shorted to ground, sensor has failed, or ECM has failed (such a failure
is unlikely).
0177 08
Temperature Sensor
This diagnostic code is associated with temperature sensor
(transmission oil). FMI 08 means ECM has determined signal
(Transmission Oil).
frequency or signal pulse width is not within expected range.
Possible causes of this diagnostic code are:
Sensor failed.
Intermittent connections or poor connections.
Mechanical devices are loose.
ECM failed (such a failure is unlikely).
0247 09
CAN Data Link
This diagnostic code is recorded when machine ECM stops receiving
Abnormal Update.
information on CAN data link.
0262 03
Power Supply (5V)
This diagnostic code is recorded when powertrain ECM reads sensor
Voltage Above Normal.
supply circuit voltage as higher than normal, due to shorted sensor
supply output to battery, or faulty transmission oil temperature sensor.
When this code is generated, lockup clutch is disabled, there is
hesitation during direction shifts and calibrations will not function.
0262 04
Power Supply (5V)
This diagnostic code is associated with sensor power supply. FMI 04
Shorted to Ground.
means ECM has determined sensor circuit voltage is below normal due
to failed sensor, circuit is shorted to ground, or failed ECM (such a
failure is unlikely).
0007 00-14