TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
0882 03
427-B1877
N OT E
This test procedure may create other diagnostic codes. Ignore these created diag-
nostic codes and clear these diagnostic codes when original diagnostic code has
been corrected. Ensure diagnostic code CID 882 FMI 03 is active before perform-
ing this procedure.
1. Check implement lockout solenoid energize  1. If each resistance measurement is
circuit for a short to +battery circuit.
greater than 5,000 Ohms, go to Test 2.
(a) Turn engine start switch and battery
2. If each resistance measurement is not
disconnect switch to OFF position (TM
greater than 5,000 Ohms, there is a
5-3805-290-10).
short between J2-2 (G962 OR) and
(b) Disconnect wiring harness connectors
circuit that has a low resistance
from implement lockout solenoid (WP
measurement. Replace wiring harness
0188 00) and machine ECM (WP 0052
in question (WP 0169 00 thru WP 0175
00).
00).
(c) At ECM wiring harness connector,
measure resistance from contact J2-2
(wire G962 OR) to all contacts used in
ECM wiring harness connectors.