TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check wiring harness.
2326 05 - Continued.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Remove jumper wire from contact
1 to 2.
(c) Reconnect solenoid valve to wiring
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
1. If resistance is greater than 5,000 Ohms
implement ECM, measure
(no continuity), replace wiring harness in
resistance between contacts J2-8
question (WP 0195 00 thru WP 0201 00).
(wire R799-BR) and contact J1-61
2. If resistance is from 6 to 12 Ohms, exit
(wire P945-OR).
this procedure and perform this
troubleshooting procedure again. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).