TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Observe ON/OFF status of
2328 05 - Continued.
diagnostic code indicator.
(d) At wiring harness connector for
1. If diagnostic code indicator remains
active, go to Test 2.
between contact 1 (wire P946-BR)
2. If diagnostic code indicator is inactive,
and contact 2 (wire R799-BR).
repeat this test in order to verify failure.
replace wiring harness in question (WP
0195 00 thru WP 0201 00). Approximate
resistance of a proportional solenoid
valve is from 6 to 12 Ohms.
2. Check wiring harness.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Remove jumper wire from contact
1 to 2.
(c) Reconnect solenoid valve to wiring
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
implement ECM, measure
resistance between contacts J2-8
question (WP 0195 00 thru WP 0201 00).
(wire R799-BR) and contact J1-62
(wire P946-BR).
this procedure and perform this
troubleshooting procedure again. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
0009 00-281