Figure 18. Brake Valve.
Figure 21. Seat Switch.

Field Maintenance Manual For M400T And M400W
Page Navigation
  118    119    120    121    122  123  124    125    126    127    128  
img
. .
TM 5-3805-292-23
0007
HYDROSTATIC SYSTEM CONTINUED
0007
Mechanically Centering Pilot Servo Piston
0007
WARN I N G
For the following test, machine must be raised up on supports until tires/tracks are off
ground.
Perform all checks from side ofmachine. Keep personnel and objects clear of tracks and
tires.
Failure to follow this warning may result in injuryor death to personnel.
1. If hydraulic oil is not at operating temperature:
a. Start engine. Run at full throttle and hold implement joystick in rollback position for 30 seconds
(TM 5-3805-292-10).
b. Return implement joystick to neutral for 15 seconds.
c.
Repeat steps a and b until temperature of oil is at least 125F (52C).
d. Shut down engine (TM 5-3805-292-10).
2. Tilt ROPS (WP 0134).
3. For right hand side track, disconnect and cap two pilot lines (Figure 20, Item 2).
4. Connect jumper hose to two ports (Figure 20, Item 1).
Figure 20. Bypassing Pilot Lines.
0007
0007-21