Figure 13. Male Test Quick Disconnect.
Checking Circuit Relief Valve Pressure - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  114    115    116    117    118  119  120    121    122    123    124  
img
.
TM 5-3805-292-23
0007
HYDROSTATIC SYSTEM CONTINUED
Checking Circuit Relief Valve Pressure - Continued
0007
9. Bypass seat switch (Figure 15, Item 2) with jumper (Figure 15, Item 1).
Figure 15. Seat Switch.
0007
10. Buckle seatbelt.
11. Start engine (TM 5-3805-292-10).
12. Hold door switch (Figure 16, Item 1) closed.
Figure 16. Door Switch.