TM 5-3805-292-23
0171
DISASSEMBLY CONTINUED
N OT E
Note orientation of 90 fittings prior to removal to aid in installation.
26. Remove two 90 elbows (Figure 8, Item 2) and locknuts (Figure 8, Item 3) from hydraulic plate (Figure 8, Item
1).
Figure 8. 90 Elbows.
0171
END OF TASK
CLEANING AND INSPECTION
000171
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low-toxic material. However, it may be irritating to the eyes and skin. Use protective
gloves and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
END OF TASK