AIR PURGE ON IMPLEMENT HYDRAULIC SYSTEM
Figure 18. Signal Pressure Connector.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  339    340    341    342    343  344  345    346    347    348    349  
img
.
TM 5-3805-298-23-2
0166
AIR PURGE ON IMPLEMENT HYDRAULIC SYSTEM CONTINUED
1. Turn ignition switch and battery disconnect switch to OFF position (TM 5-3805-298-10).
2. Apply sealant on threads of one end of hose (Figure 17, Item 2).
3. Install female hose coupling (Figure 17, Item 1) on hose (Figure 17, Item 2).
Figure 17. Hose Assembly.