TM 5-3805-262-342-4. ENGINE TROUBLESHOOTING (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION10. LOW ENGINE OIL PRESSURE (Cont).Step 6.(Cont) .Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.Wear protective goggles and gloves and use only in a well ventilatedarea. Avoid contact with skin, eyes and clothes and don’t breathevapors. Do not use near open flame or excessive heat and don’t smokewhen using it. Failure to do so could cause serious injury. If you be-come dizzyattentionwith largewith waterwhile using cleaning solvent, get fresh air-and medicalimmediately. If contact with skin or clothes is made, flushamounts of water.If contact with eyes is made, wash eyesand get medical aid immediately.Compressedonly withair used for cleaning purpose will not exceed 30 psi. Useeffective chip guarding and personal protective equipment(goggles/shield, gloves, etc). Failure to do so could cause seriousinjury to eyes and possible blindness.If you hurt your eyes or if aforeign object is blown into your eyes, seek medical attention immedi-ately.Clean oil suction tube and screen by immersing in cleaning sol-vent P-D-680 and soaking for several minutes. Remove from clean-ing solvent, and use compressed air to clear blockage from tubeand screen.Put oil suction tube in position and connect nut to fitting onoil pump.Tighten oil suction tube nut 90 to 100 lb-ft using Crowsfootwrench. Reinstall oil pan (page 3-90).2-37