TM 5-3805-262-34INSTALLATIONa. Install sight gage (5) in hydraulic reservoir (4).When using chain hoist to remove or install parts, be sure chain hoistis securely fastened to part and that all slack in chain is taken up.Failure to do so could cause serious injury due to part falling on you.If you are injured by falling equipment, obtain medical aid immediately.b. Connect chain hoist to hydraulic reservoir (4). Position hydraulic reservoirabove front access door. Slowly lower hydraulic reservoir while guiding itthrough access door.c. Install and tighten three capscrews (3), lock washers (2), and nuts (1).d. Install hydraulic filter assembly and connect hydraulic pump hose, hydraulicfilter hose, and air hose to hydraulic reservoir (4) (refer to TM5-3805-262-20).e. Fill hydraulic reservoir (4) with hydraulic oil (refer to TM 5-3805-262-20).LEGEND1. Nuts (3)2. Lock washers (3)3. Capscrews (3)4. Hydraulic reservoir5. Sight gage3-753