TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
MACHINE ECM - CONTINUED
0007 00
Table 2. MID 081 - Machine Control - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
1406 06
Solenoid (Clutch 6)
This diagnostic code is associated with clutch 6 solenoid (first speed).
Short to Ground.
FMI 06 means ECM has determined solenoid current is above normal.
Possible causes of this diagnostic code are: solenoid energize circuit is
shorted to ground, solenoid has failed, or ECM has failed (such a failure
is unlikely). When this diagnostic code occurs, ECM will disable this
transmission solenoid.
1834 04
Ignition Switch
This diagnostic code is recorded when ECM reads keystart switch
Short to Ground.
signal voltage and voltage is too low. Possible causes of this failure are:
signal circuit in machine harness is shorted to ground or ECM has failed
(such a failure is unlikely). ECM will log diagnostic code.