Table 2. Machine Control System - Continued.
Table 2. Machine Control System - Continued.

Manual 1 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  518    519    520    521    522  523  524    525    526    527    528  
img
. . .
TM 5-3805-290-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
0271 03
427-B1855
N OT E
This test procedure may create other diagnostic codes. Ignore these created diag-
nostic codes and clear these diagnostic codes when original diagnostic code has
been corrected. Ensure diagnostic code CID 0271 FMI 03 is active before per-
forming this procedure.
1. Check alarm energize circuit for a short to  1. If each resistance measurement is
greater than 5,000 Ohms, go to Test 2.
+battery circuit.
2. If each resistance measurement is not
(a) Turn engine start switch and battery
greater than 5,000 Ohms, there is a
disconnect switch to OFF position (TM
short in wiring harness between IC-23
5-3805-290-10).
(H414 YL) and circuit that has a low
(b) Disconnect wiring harness connectors
resistance measurement. Replace
from alarm and instrument cluster (WP
wiring harness in question (WP 0169
0051 00).
00 thru WP 0175 00).
(c) At instrument cluster wiring harness
connector, measure resistance from
contact IC-23 (wire H414 YL) to all
contacts used in instrument cluster
wiring harness connectors.
0009 00-26