Table 2. Machine Control System - Continued.
Table 2. Machine Control System - Continued.

Manual 1 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  536    537    538    539    540  541  542    543    544    545    546  
img
. . . . .
TM 5-3805-290-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
4. Check autoshift switch operation. Refer to  1. If resistance complies with table,
0368 03 -
Autoshift Switch Status, Table 3, in this
switch is operating correctly. Go to
Cont.
section.
Test 5.
(a) Remove jumper installed in Test 3.
2. If resistance does not comply with
(b) Wiring harness remains disconnected
table, replace autoshift switch (WP
from ride control switch.
0049 00).
(c) Place switch in MANUAL position
(TM 5-3805-290-10).
(d) Connect one lead from multimeter to
contact 2 (wire 202 BK) of switch
harness connector.
(e) One at a time, connect other lead from
multimeter to contacts 1, 3, 4, and 6,
and measure resistance to contact 2
(wire 202 BK).
(f) Place switch in AUTO position (TM 5-
3805-290-10).
(g) One at a time, connect other lead from
multimeter to contacts 1, 3, 4, and 6,
and measure resistance to contact 2
(wire 202 BK).
(h) Rotate switch to VSC position (TM 5-
3805-290-10).
(i) One at a time, connect other lead from
multimeter to contacts 1, 3, 4, and 6,
and measure resistance to contact 2
(wire 202 BK).
5. Verify diagnostic code remains active.
1. If CID 0368 FMI 03 is active, replace
(a) Inspect and clean harness connector
machine ECM (WP 0052 00).
contacts.
2. If CID 0368 FMI 03 is not active, initial
(b) Reconnect all harness connectors.
diagnostic code was probably caused
(c) Turn battery disconnect switch and
by a poor electrical connection or a
engine start switch to ON position (TM
short at a harness connector that was
5-3805-290-10).
disconnected and reconnected.
(d) Operate machine (TM 5-3805-290-
Resume normal machine operation.
10).
(e) Connect MSD (WP 0006 00) and check
status of CID 0368 FMI 03.
0009 00-44


Privacy Statement