Margin Pressure Adjustment.
Case Drain Pressure.

Manual 1 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  796    797    798    799    800  801  802    803    804    805    806  
img
.
TM 5-3805-290-23-1
HYDRAULIC SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0017 00
PISTON PUMP PRESSURE TEST AND ADJUSTMENT - CONTINUED
7.
Standby Pressure.
a.
Remove right chassis cover (WP 0107 00) for
access to bank valve (7).
b.
Connect pressure gage to hose.
c.
Install other end of hose assembly on test port (6)
for piston pump pressure. Test port for piston
pump pressure is on top of bank valve (7).
427-B0956
N OT E
DO NOT move any work tool controls to check pump standby pressure.
d.
Run engine at high idle. Observe pressure on test port for piston pump pressure. Pump standby pressure is 290 30
psi (2,000 207 kPa).
e.
Stop engine (TM 5-3805-290-10).
f.
Remove all test equipment.
0017 00-9