Table 4. Implement Control - Continued.
Table 5. Switch Continuity - CID 0490 Implement Lockout Switch.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  787    788    789    790    791  792  793    794    795    796    797  
img
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check for a shorted wiring harness.
2328 06 - Continued.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Solenoid valve from previous test
remains disconnected.
(c) Disconnect wiring harness from
implement ECM (WP 0060 00).
(d) At wiring harness connector for
1. If resistance is less than 5,000 Ohms,
implement ECM, measure
replace wiring harness in question (WP
resistance between contact for
0195 00 thru WP 0201 00).
failed solenoid circuit J1-62 (wire  2. If resistance is greater than 5,000 Ohms
P946-BR) and contact J2-8 (ground
(no continuity), exit this procedure and
wire R799-BR).
perform this troubleshooting procedure
again. Also, recheck if diagnostic code
indicator is active for this diagnostic
code. If cause is not found, replace
implement ECM (WP 0060 00).