TM 5-3805-292-23
0007
HYDROSTATIC SYSTEM CONTINUED
Checking Circuit Relief Valve Pressure
0007
WARN I N G
For the following test, machine must be rased up on supports until tires/tracks are off
i
ground.
Perform all checks from side of machine.
Failure to follow this warning may result in injuryor death to personnel.
1. If hydraulic oil is not at operating temperature:
a. Start engine. Run at full throttle and hold implement joystick in rollback position for 30 seconds
(TM 5-3805-292-10).
b. Return implement joystick to neutral for 15 seconds.
c.
Repeat steps a and b until temperature of oil is at least 125F (52C).
d. Shut down engine (TM 5-3805-292-10).
2. Remove four bolts (Figure 10, Item 1) and plate (Figure 10, Item 2).
Figure 10. Access Plate.
0007