TM 5-3805-292-23
0169
NITROGEN DISCHARGING/CHARGING CONTINUED
000169
WARN I N G
DO NOT disconnect or remove any hydraulicsystem line or fitting unless engine is shut
down and hydraulic system pressure has been relived. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin,
causing injury or death to personnel.
Use piece of cardboard, newspaper, or wood to check for pressurized leaks to prevent
fluid from penetrating the skin. Failure to follow this warning may cause injury or death to
personnel.
1. Remove two hoses (Figure 11, Item 1) from fittings (Figure 11, Item 2).
Figure 11. Hoses.
0169
0169-9