Figure 16. Weatherproof Connector - Male.
ELECTRICAL GROUND POINTS

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
img
.
TM 5-3805-298-23-2
0174
WEATHERPROOF CONNECTOR REPAIR CONTINUED
NOTE
Perform steps 6 and 7 only if terminal was removed.
Install terminals as noted during removal.
6. Using wire stripping tool, strip insulation from wire (Figure 17, Item 1) equal to depth of terminal (Figure 17,
Item 2).
7. Using crimping tool, securely crimp terminal (Figure 17, Item 2) on wire (Figure 17, Item 1).
Figure 17. Male Terminal.
0174
8. If removed, install sleeve (Figure 18, Item 4) and seal (Figure 18, Item 3) on wiring harness 
(Figure 18, Item 5).
9. Install terminal (Figure 18, Item 2) into connector body (Figure 18, Item 6). Pull wire to ensure terminal is
locked in place on connector body.
10. Slide seal (Figure 18, Item 3) into connector body (Figure 18, Item 6).
11. Slide shell (Figure 18, Item 4) up on wiring harness (Figure 18, Item 5) and onto connector body (Figure 18,
Item 6).
12. Install terminal lock (Figure 18, Item 1) on connector body (Figure 18, Item 6).
Figure 18. Weatherproof Connector - Male.
0174
END OF TASK
0174-19