Figure 9. Shuttle Interlock Relay and Neutral Relay.
Table 1. Engine Does Not Crank or Cranks Slowly - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  249    250    251    252    253  254  255    256    257    258    259  
img
. . . . . .
TM 5-2420-231-23-1
0013
Table 1. Engine Does Not Crank or Cranks Slowly - Continued.
013
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
17. Using a digital multimeter, mea-
Engine Does Not Crank or
Resistance 5.0 Ohms or Less -
sure resistance between shift lever
Proceed to step 18.
Cranks Slowly - Continued
wiring harness connector (WP
Resistance Greater Than 5.0 Ohms -
0007, Figure 21) terminal 6 and
Replace front console wiring harness
neutral relay wiring harness con-
(WP 0162).
nector (WP 0007, Figure 22) termi-
Proceed to Test Step 7.
nal 85. Resistance should be 5.0
ohms or less.
18. Using a digital multimeter, test for
Continuity - Replace front console
continuity between shift lever wir-
wiring harness (WP 0162).
ing harness connector (WP 0007,
Proceed to Test Step 7.
Figure 21) terminal 6 and machine
No Continuity - Proceed to step 19.
ground. There should be no conti-
nuity.
19. Using a digital multimeter, mea-
Resistance 5.0 Ohms or Less -
sure resistance between neutral
Proceed to step 20.
relay wiring harness connector
Resistance Greater Than 5.0 Ohms -
(WP 0007, Figure 22) terminal 86
Verify that front console ground (Figure
and machine ground. Resistance
10, Item 1) is clean and tight. If front
should be 5.0 ohms or less.
console ground is OK, replace front
console wiring harness (WP 0162).
Proceed to Test Step 7.
Figure 10. Front Console Ground.