TM 5-3805-262-34
Disassembly (SHEET 2 OF 2)
(4)
If sleeve (5) is loose, use pliers to grip it and pull from oil pump (6).
Discard sleeve.
(5) Loosen and remove four capscrews securing pump cover to pump body. Remove
pump cover from body.
CLEANING
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
Wear protective goggles and gloves and use only in a well ventilated
area. Avoid contact with skin, eyes and clothes and dont breathe
vapors. Do not use near open flame or excessive heat and dont smoke
when using it. Failure to do so could cause serious injury. If you be-
come dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush
with large amounts of water.
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
(1)
Clean spring (3) , valve (4), pump cover and pump body using cleaning sol-
vent P-D-680. Dry using clean cloths.
Compressed air used for cleaning purposes will not exceed 30 psi. Use
only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc). Failure to do so could cause serious
injury to eyes and possible blindness.
If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention
immediately.
( 2 )
Clean valve (4) oil holes using compressed air.
4-75