TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
2326 03
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
Solenoid Valve Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the lift arms may have excessive drift.
2326 05
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects an incomplete
Solenoid Valve Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noid is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the lift linkage will not lower.
2326 06
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
Solenoid Valve Current
ground in the electrical path from the ECM to the solenoid. The possible
Above Normal or
causes for this diagnostic code are the internal windings for the solenoid
Grounded Circuit
have low impedance, the internal windings for the solenoid are shorted,
and the signal circuit from the ECM to the solenoid is shorted to ground.
When this code is generated, the lift linkage will not lower.
2328 03
Dump Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
Solenoid Valve Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the bucket may have excessive drift.
0007 00-47