• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 3. MID 082 Implement - Continued.
Table 3. MID 082 Implement - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  398    399    400    401    402  403  404    405    406    407    408  
img
. . . .
TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
2326 03
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
0009 00-273
Solenoid Valve Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the lift arms may have excessive drift.
2326 05
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects an incomplete
0009 00-275
Solenoid Valve Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noid is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
high impedance.
The internal windings for the solenoid are
open.
When this code is generated, the lift linkage will not lower.
2326 06
Lower Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
0009 00-277
Solenoid Valve Current
ground in the electrical path from the ECM to the solenoid. The possible
Above Normal or
causes for this diagnostic code are the internal windings for the solenoid
Grounded Circuit
have low impedance, the internal windings for the solenoid are shorted,
and the signal circuit from the ECM to the solenoid is shorted to ground.
When this code is generated, the lift linkage will not lower.
2328 03
Dump Anti-Drift
This diagnostic code is recorded when the ECM detects a short to
0009 00-278
Solenoid Valve Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the bucket may have excessive drift.