0492 05
Auxiliary Lever
This diagnostic code is recorded when the ECM detects an incomplete
Rearward Solenoid
electrical path. The electrical path from the ECM to the solenoid back
Valve Current Below
to the ECM is incomplete. The possible causes for this diagnostic code
Normal or Open Circuit
are:
The signal circuit from the ECM to the sole-
noid is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the implement function that is associated
with the third function lever REARWARD will not operate and after
clearing the diagnostic code, the third function lever must be recentered
before movement of the third function is allowed.
0492 06
Auxiliary Lever
This diagnostic code is recorded when the ECM detects a short to
Rearward Solenoid
ground in the electrical path from the ECM to the solenoid. The possible
Valve Current Above
causes for this diagnostic code are the internal windings for the solenoid
Normal or Grounded
have low impedance, the internal windings for the solenoid are shorted,
Circuit
and the signal circuit from the ECM to the solenoid is shorted to ground.
When this code is generated, the implement function that is associated
with the third function lever REARWARD will not operate and after
clearing the diagnostic code, the third function lever must be recentered
before movement of the third function is allowed.
0492 13
Auxiliary Lever
This diagnostic code is recorded when the implement ECM determines
Rearward Solenoid
Valve Out of Calibration diagnostic code are new software has been flashed and the calibration
of the valve has failed.
0590 02
Cat Data Link
This failure results in events that are logged against an ECM that can
Communication with
not be explained. The Implement ECM cannot communicate with the
Engine EC Data Erratic,
Engine ECM or the ECM appears to work intermittently.
Intermittent, or Incorrect
0590 09
Cat Data Link
This diagnostic code is recorded when the implement ECM is unable
Communication with
to communicate with the engine ECM. The possible cause of this
Engine EC Abnormal
diagnostic code is the data link wire between the implement ECM and
Update
the engine ECM has failed. When this code is generated, implement
valve calibrations will not work due to unavailable engine speed input,
and the pilot on/off solenoid valve will shut off when all the levers are
in the HOLD position.