TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0491 05
Auxiliary Lever Forward
This diagnostic code is recorded when the ECM detects an incomplete
Solenoid Valve Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noid is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the implement function that is associated
with the third function lever FORWARD will not operate and after
clearing the diagnostic code, the third function lever must be
recentered before movement of the third function is allowed.
0491 06
Auxiliary Lever Forward
This diagnostic code is recorded when the ECM detects a short to
Solenoid Valve Current
ground in the electrical path from the ECM to the solenoid. The possible
Above Normal or
causes for this diagnostic code are the internal windings for the solenoid
Grounded Circuit
have low impedance, the internal windings for the solenoid are shorted,
and the signal circuit from the ECM to the solenoid is shorted to ground.
When this code is generated, the implement function that is associated
with the third function lever FORWARD will not operate and after
clearing the diagnostic code, the third function lever must be recentered
before movement of the third function is allowed.
0491 13
Auxiliary Lever Forward This diagnostic code is recorded when the implement ECM determines
Solenoid Valve Out of
Calibration
diagnostic code are new software has been flashed and the calibration
of the valve has failed.
0492 03
Auxiliary Lever
This diagnostic code is recorded when the ECM detects a short to
Rearward Solenoid
+battery in the electrical path that goes from the ECM to the solenoid
Valve Voltage Above
back to the ECM. The possible causes for this diagnostic code are the
Normal or Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the implement function that is associated with the
third function lever REARWARD will operate continuously.
0007 00-43