TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0490 04
Rocker Switch
This diagnostic code is recorded when the status of both the normally
(Implement Lockout)
open inputs and normally closed inputs are grounded. This switch has
Voltage Below Normal
two inputs to the ECM. The inputs are normally open and normally
or Shorted Low
closed. During proper operation, one input is open and the other input
is grounded. The possible causes of this diagnostic code are:
The normally open circuit is shorted to
ground while the normally closed circuit is
grounded through the switch.
The normally closed circuit is shorted to
ground while the normally open circuit is
grounded through the switch.
The normally open circuits and the normally
closed circuits are shorted to ground in the
harness.
The normally open circuits and normally
closed circuits are shorted together. The
switch must be in one specific position.
The switch has failed.
When this code is generated, the implements will not work.
0491 03
Auxiliary Lever Forward
This diagnostic code is recorded when the ECM detects a short to
Solenoid Valve Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to +battery and
the return circuit from the solenoid is shorted to +battery. When this
code is generated, the implement function that is associated with the
third function lever and the implement function that is associated with
the third function lever FORWARD will operate continuously.
0007 00-42