TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check wiring harness.
0357 05 - Continued.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Remove jumper wire from contact
1 to 2.
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
implement ECM, measure
resistance between contacts J1-50
failed. Replace wiring harness in
(wire H716-WH) and contact J1-51
question (WP 0195 00 thru WP 0201 00).
(wire E921-PK).
2. If resistance is from 6 to 12 Ohms,
this procedure and repeat this
troubleshooting procedure. Also,
recheck if diagnostic code indictor is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
427-C1659
N OT E
0357 06
All solenoid return lines connect to contact J1-50 (wire H716-WH) of implement
ECM.
The following procedure may create other diagnostic codes. Ignore these created
diagnostic codes and clear diagnostic codes when original diagnostic code is cor-
rected.
Ensure diagnostic code indicator is active and diagnostic code is active.
1. Check solenoid.
(a) Turn battery disconnect and engine
start switches to ON position (TM
5-3805-291-10).