TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
0356 05 - Continued.
12 Ohms.
2. Check wiring harness.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Remove jumper wire from contact
1 to 2.
(c) Reconnect solenoid valve to wiring
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
implement ECM, measure
resistance between contacts J1-50
failed. Replace wiring harness in
(wire H716-WH) and contact J1-52
question (WP 0195 00 thru WP 0201 00).
(wire E922-GN).
2. If resistance is from 6 to 12 Ohms, exit
this procedure and perform this
troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
427-C1658
N OT E
0356 06
All solenoid return lines connect to contact J1-50 (wire H716-WH) of implement
ECM.
The following test procedure may create other diagnostic codes. Ignore these
created diagnostic codes and clear diagnostic codes when original diagnostic
code is corrected.
Ensure diagnostic code indicator is active and diagnostic code is active.