TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check solenoid.
0356 06 - Continued.
(a) Turn battery disconnect and engine
start switches to ON position (TM
5-3805-291-10).
(b) Observe ON/OFF status of
diagnostic code indicator.
(c) Disconnect dump solenoid from
1. If diagnostic code indicator remains
wiring harness (WP 0218 00).
active, harness or implement ECM has
failed. Go to Test 2.
2. If diagnostic code indicator is inactive,
repeat this test to verify failure. Replace
(WP 0195 00 thru WP 0201 00).
2. Check for shorted wiring harness.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Solenoid valve remains
disconnected.
(c) Disconnect wiring harness from
implement ECM (WP 0060 00).
(d) At wiring harness connector for
implement ECM, measure
(continuity), harness has failed. Replace
resistance between contact for
wiring harness in question (WP 0195 00
thru WP 0201 00).
E922-GN) and contact J1-50
(ground) (wire H716-WH).
is correct. Exit this procedure and repeat
this troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
N OT E
0356 13
Ensure diagnostic code is active and diagnostic code indicator is
active.
(a) Calibrate main control valve (WP
(b) Recheck diagnostic code.
(c) Ensure diagnostic code is active.