Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  723    724    725    726    727  728  729    730    731    732    733  
img
. . .
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check solenoid.
0356 06 - Continued.
(a) Turn battery disconnect and engine
start switches to ON position (TM
5-3805-291-10).
(b) Observe ON/OFF status of
diagnostic code indicator.
(c) Disconnect dump solenoid from
1. If diagnostic code indicator remains
wiring harness (WP 0218 00).
active, harness or implement ECM has
failed. Go to Test 2.
2. If diagnostic code indicator is inactive,
repeat this test to verify failure. Replace
solenoid or wiring harness in question
(WP 0195 00 thru WP 0201 00).
2. Check for shorted wiring harness.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Solenoid valve remains
disconnected.
(c) Disconnect wiring harness from
implement ECM (WP 0060 00).
(d) At wiring harness connector for
1. If resistance is less than 5,000 Ohms
implement ECM, measure
(continuity), harness has failed. Replace
resistance between contact for
wiring harness in question (WP 0195 00
failed solenoid circuit J1-52 (wire
thru WP 0201 00).
E922-GN) and contact J1-50
2. If resistance is greater than 5,000 Ohms
(ground) (wire H716-WH).
(no continuity), harness circuit resistance
is correct. Exit this procedure and repeat
this troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
N OT E
0356 13
Ensure diagnostic code is active and diagnostic code indicator is
active.
Check calibration of main control valve.
(a) Calibrate main control valve (WP
0017 00).
(b) Recheck diagnostic code.
(c) Ensure diagnostic code is active.