TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Observe ON/OFF status of
0358 05 - Continued.
diagnostic code indicator.
(d) At wiring harness connector for
1. If diagnostic code indicator remains
solenoid, place a jumper wire
active, harness or implement ECM has
between contact 1 (wire F852-YL)
failed. Go to Test 2.
and contact 2 (wire K927-BU).
2. If diagnostic code indicator is inactive
solenoid valve or connecting harness has
failed. Repeat this test to verify failure.
harness in question (WP 0195 00 thru
WP 0201 00).
2. Check wiring harness.
(a) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
(b) Remove jumper wire from contact
1 to 2.
(c) Reconnect solenoid valve to wiring
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
implement ECM, measure
resistance between contacts J2-4
failed. Replace wiring harness in
(wire K927-BU) and contact J2-2
question (WP 0195 00 thru WP 0201 00).
(wire F852-YL).
2. If resistance is less than 5,000 Ohms,
this procedure and repeat this
troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
0009 00-228