TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Turn engine start switch to ON
0492 03 - Continued.
position (TM 5-3805-291-10).
(d) At wiring harness connector for
1. If voltage is approximately battery
implement ECM, measure voltage
voltage, replace wiring harness in
between contact J1-60 (wire J813-
question (WP 0195 00 thru WP 0201 00).
BK) and contact J1-58 (wire E919- 2. If voltage is approximately 0 DCV, go to
YL).
Test 3.
3. Check if diagnostic code remains active.
(a) Turn engine start switch to OFF
position (TM 5-3805-291-10).
(b) Disconnect and inspect all wiring
harness connectors and reconnect.
Refer to Electrical Connectors
necessary.
(c) Turn engine start switch to ON
position (TM 5-3805-291-10).
(d) Operate machine and use
1. If diagnostic code is active, exit this
messenger to ensure CID 0492 FMI
procedure and repeat this
03 is active (TM 5-3805-291-10).
troubleshooting procedure. If cause of
diagnostic code is not found, replace
implement ECM (WP 0060 00).
2. If diagnostic code is not active, initial
diagnostic code was probably caused by
poor electrical connection at a wiring
harness connector that was disconnected
and reconnected. Resume normal
machine operation.
0009 00-250