TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(b) Remove jumper wire from contact
0492 05 - Continued.
1 to 2.
(c) Reconnect solenoid valve to wiring
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
implement ECM, measure
resistance between contacts J1-60
Replace wiring harness in question (WP
(wire J813-BK) and contact J1-58
0195 00 thru WP 0201 00).
(wire E919-YL).
2. If resistance is from 6 to 12 Ohms,
harness circuit resistance is correct. Exit
this procedure and perform this
troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
N OT E
Ohms.
427-C1667
N OT E
0492 06
All solenoid return lines connect to contact J1-60 (wire J813-BK) of implement
ECM.
The following test procedure may create other diagnostic codes. Ignore these
created diagnostic codes and clear diagnostic codes when original diagnostic
code is corrected.
Ensure diagnostic code indicator is active and diagnostic code is active.