• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  769    770    771    772    773  774  775    776    777    778    779  
img
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If resistance measured is less than 5
0967 09 - Continued.
Ohms for each measurement, implement
ECM may have failed. Exit this
procedure and perform this diagnostic
code procedure again. Replace
implement ECM (WP 0060 00) if cause
of diagnostic code is not found.
2. If resistance measured is greater than
5,000 Ohms for one or more
measurements, wiring harness has failed.
Replace wiring harness in question (WP
0195 00 thru WP 0201 00).
0009 00-265


Privacy Statement