TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
Table 3. MID 082 Implement.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
This code is recorded when the implement ECM reads the voltage of
0041 03
8 VDC Supply Voltage
the sensor supply circuit (wire A105 OR) as higher than normal. The
Above Normal or
sensor supply circuit (wire A105 OR) is shorted to the +battery, a
Shorted High
sensor has failed, or the implement ECM has failed. When this code is
generated, components that receive power from the sensor supply will
not be available, the steering pump will be full on, and the steering
pressure will be at relief.
This diagnostic code is recorded when the implement ECM reads the
0041 04
8 VDC Supply Voltage
voltage of the sensor supply circuit (A105 OR) and the voltage is
Below Normal or
below normal. When this code is generated, components that receive
Shorted Low
power from the sensor supply will not be available.
0168 00
Battery Voltage Above
This diagnostic code is recorded when the implement ECM identifies
Normal
a system voltage that is above 24.0 DCV. This code is generated when
the voltage regulator is not operating properly, or jump starting. This
code has no effect on performance.
0168 01
Battery Voltage Below
The diagnostic circuit of the implement ECM identifies a system
Normal
voltage that is below 18 DCV. This code is generated, the system
voltage remains low for an extended time after the engine is started,
there is a connection with high impedance between the battery and the
implement ECM, there is a connection with high impedance between
the implement ECM and system ground, or one set of batteries is
disconnected with the key in the ON position. The engine must not be
running. When this code is generated, implement functions will not
work and the pilot on/off solenoid valve for the implements will de-
energize.
The implement ECM detects that one or more of the programmable
0268 02
Programmed Parameter
Fault Data Erratic,
parameters are not properly configured. When this code is generated,
Intermittent, or Incorrect
any unprogrammed parameters are set to the default value, if the
default setting of the configuration is not changed to the appropriate
model, a diagnostic code is generated. The diagnostic code is
generated in order to warn the service personnel that the module must
be configured.
0007 00-27