TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0350 08
Lift Linkage Position
This diagnostic code is recorded when the implement ECM records a
Sensor Abnormal
signal from the rotary position sensor for the lift linkage that has an
abnormal frequency, abnormal pulse width or an abnormal period. The
Period
rotary position sensor is Pulse Width Modulation (PWM). The signal
wire for the sensor connects to contact J2-32 (wire C530 BU) of the
implement ECM. The possible causes of this diagnostic code are the
circuit for the +battery to the sensor has a intermittent connection, the
return circuit from the sensor has a intermittent connection, the signal
circuit from the sensor has a intermittent connection, or the sensor has
failed. When this code is generated, lift kickouts, snubbing, and float
will not operate, or tilt kickouts, dump rate control, FRAC, and dump
stop snubbing will not operate. The active fault must be removed before
the implement features will work properly.
0350 13
Lift Linkage Position
This diagnostic code is recorded when the implement ECM records a
Sensor Out of
signal from the rotary position sensor for the lift linkage that is out of
Calibration
calibration. The rotary position sensor is pulse width modulation
(PWM). The signal wire for the rotary position sensor connects to
contact J2-32 (wire C530 BU) of the implement ECM. The possible
causes of this diagnostic code are new software has been installed, and
the sensor has not been calibrated or the position sensor is above or the
position sensor is below the calibration range for more than three
seconds. When this code is generated, lift kickouts, snubbing, and float
will not operate, or tilt kickouts, dump rate control, FRAC, and dump
stop snubbing will not operate. The active fault must be removed before
the implement features will work properly. The calibration procedure
for the implement valves may not function properly.
0351 00
Tilt Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Data Valid but
that the signal for the tilt linkage position sensor is too high. This
Above Normal
diagnostic code is recorded when the implement ECM has read a sensor
Operating Range
value that is greater than the calibrated upper range of the sensor. The
tilt linkage position sensor is a PWM sensor. The signal wire for the tilt
linkage position sensor connects to connector contact J2-33 (wire H718
GY) of the implement ECM. The possible causes of this diagnostic code
are the rotation or replacement of the tilt linkage position sensor without
proper recalibration or the position sensor could rotate farther than
normal in one direction. When this code is generated, the tilt kickouts,
dump stop snubbing, FRAC, and dump rate control may not work
correctly, or if the diagnostic code is active for three seconds, the 35013
diagnostic code will become active.
0007 00-30