TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0351 01
Tilt Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Data Valid but
that the signal for the tilt linkage position sensor is too low. The
Below Normal Operating
diagnostic code is recorded when the implement ECM reads a value
Range
that is lower than the calibrated value. The tilt linkage position sensor
is a PWM sensor. The signal wire for the tilt linkage position sensor
connects to connector contact J2-33 (wire H718 GY) of the implement
ECM. The possible causes of this diagnostic code are the rotation or
replacement of the tilt linkage position sensor without proper
recalibration or the position sensor could rotate farther than normal in
one direction the implement ECM would then record a FMI 01 fault).
The tilt cylinder snubbing, and the tilt kickouts may not work correctly.
If the diagnostic code is active for three seconds, then the 351-13
diagnostic code will become active. When this code is generated, the
tilt kickouts, dump stop snubbing, FRAC, and dump rate control may
not work correctly, or if the diagnostic code is active for three seconds,
the 350-13 diagnostic code will become active.
0351 03
Tilt Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Above
that the signal for the tilt linkage position sensor is stuck at a high
Normal or Shorted High
voltage or has an open circuit. The tilt linkage position sensor is a PWM
sensor. The signal wire for the tilt linkage position sensor connects to
connector contact J2-33 (wire H718 GY) of the implement ECM. The
possible causes of this diagnostic code are a shorted harness, an open
circuit, a failed sensor, the implement ECM has failed. When this code
is generated, tilt kickouts, dump rate control, FRAC, and dump stop
snubbing will not operate. The active fault must be removed before the
implement features will work properly.
0351 04
Tilt Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Below
that the voltage for the tilt linkage position sensor is below normal. The
Normal or Shorted Low
tilt linkage position sensor is a PWM sensor. The signal wire for the tilt
linkage position sensor connects to connector contact J2-33 (wire H718
GY) of the implement ECM. The possible causes of this diagnostic code
are a shorted harness, an open circuit in the power supply wiring for the
tilt linkage position sensor, a failed sensor, or the implement ECM may
have failed. When this code is generated, tilt kickouts, dump rate
control, FRAC, and dump stop snubbing will not operate. The active
fault must be removed before the implement features will work
properly.
0007 00-31