TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0350 01
Lift Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Data Valid but
that the signal for the lift linkage position sensor is too low. The
Below Normal Operating
diagnostic code is recorded when the implement ECM reads a value
Range
that is lower than the calibrated value. The lift linkage position sensor
is a PWM sensor. The signal wire for the lift linkage position sensor
connects to connector contact J2-32 (wire C530 BU) of the implement
ECM. Possible causes of this code are the rotation or replacement of
the lift linkage position sensor without proper calibration or position
sensor could rotate farther than normal in one direction. When this code
is generated, the lift cylinder snubbing, lift kickouts, and the lower
kickout may not work correctly, or if the diagnostic code is active for
three seconds, then the 350-13 diagnostic code will become active.
0350 03
Lift Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Above
that the signal for the lift linkage position sensor is stuck at a high
Normal or Shorted High
voltage for has an open circuit. The lift linkage position sensor is a
PWM sensor. The signal wire for the lift linkage position sensor
connects to a connector contact J2-32 (wire C530 BU) of the implement
ECM. Possible causes of this diagnostic code are a shorted harness, a
failed sensor, and open circuit, or the implement ECM has failed. When
this code is generated, lift kickouts, snubbing, and float will not operate
and tilt kickouts, dump rate control, FRAC, and dump stop snubbing
will not operate. The active fault must be removed before the implement
features will work properly.
0350 04
Lift Linkage Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Below
that the voltage for the lift linkage position sensor is below normal. The
Normal or Shorted Low
lift linkage position sensor is a PWM sensor. The signal wire for the lift
linkage position sensor connects to connector contact J2-32 (wire C530
BU) of the implement ECM. Possible causes of this diagnostic code are
a shorted harness, an open circuit in the power supply wiring for the lift
linkage position sensor, a failed sensor, or the implement ECM may
have failed. When this code is generated, lift kickouts, snubbing, and
float will not operate and tilt kickouts, dump rate control, FRAC, and
dump stop snubbing will not operate. The active fault must be removed
before the implement features will work properly.
0007 00-29