TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0352 04
Lift Lever Position
This diagnostic code is recorded when implement ECM determines that
Sensor Voltage Below
the voltage for the lift lever position sensor is too low or shorted low.
Normal or Shorted Low
The lift lever position sensor is a pulse width modulated sensor. The
possible causes for this diagnostic code are the harness between the
implement ECM and the sensor has a short to ground, the sensor has
failed, or the + battery circuit has an open. When this code is generated,
the lift function will be disabled until the diagnostic code is cleared and
the lift lever position sensor must be centered.
0352 08
Lift Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Abnormal
that the signal for the lift lever position sensor has an abnormal pulse
width, abnormal frequency, or an abnormal period. The lift lever
Period
position sensor is a PWM sensor. The signal wire for the lift lever
position sensor connects to connector contact J2-24 (wire H710 PK) of
the implement ECM. The possible causes for this diagnostic code are
the circuit for the +battery to the sensor has a intermittent connection,
the return circuit from the sensor has a intermittent connection, the
signal circuit from the sensor has a intermittent connection, or the sensor
has failed. The lift function will not operate while the diagnostic code
is active.
0352 13
Lift Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Out of
that the lift lever position sensor is out of calibration. The lift lever
position sensor is a PWM sensor. The possible causes for this diagnostic
code are the lift lever has operated outside the calibrated range for more
than three seconds. When this code is generated, implement features
will not operate and lever will operate with increased deadband.
0353 00
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Data Valid but
that the signal from the tilt lever position sensor is out of location. The
Above Normal
tilt lever sensor is a 500 Hz PWM sensor. One possible cause is the tilt
Operating Range
lever position sensor needs recalibrated. If 353-00 is active for at least
three seconds, then the 353-13 diagnostic code will become active and
353-00 diagnostic code will become inactive.
0353 01
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Data Valid but
that the signal for the tilt lever position sensor is too low. The lift lever
Below Normal Operating
position sensor is a pulse width modulated sensor. One possible cause
Range
is the tilt lever sensor needs recalibrated. If 35301 is active for at least
three seconds, then the 353-13 diagnostic code will become active and
353-01 diagnostic code will become inactive.
0007 00-33